Arctic Hydronic Air Handler for Advanced Heating and Cooling
Hydronic air handlers transfer energy from hydronic boilers and AC units around the house through the centralized ductwork. Earlier most air handlers were designed for high-temperature water sources ranging from 140-180 F. This means, the heat exchanger could have relatively undersize but do the job well.
Currently, modern high efficient energy sources are garnering more popularity as the old air handlers can’t do the job. This is where Arctic Hydronic Air Handler comes into the picture. It’s the new breed in technology and efficiency. This system has unique features like Variable Frequency Drive (VFD) and 6-row heat exchangers.
However, the Arctic series hydronic air handlers are the most efficient air handlers on the market for delivering lower temperature heating benefits. This means they can provide enough heating to hydronic heat pumps, geothermal systems, and condensing boilers. All of them work efficiently at lower temperatures.
Special Features
Heat Exchanger
The Arctic Hydronic Air Handler has six-row hydronic copper and aluminum heat exchanger with one inch in or outlines. Apart from other counterparts, the six-row heat exchanger is nearly 400% larger than others. This is why the air handlers maximize the rate of heat transfer while using lower water temperatures.
This doesn’t mean that it won’t work with traditional high-temperature boilers. Its output is up to 150,000 BTU at 190F. The heat exchanger has a special internal loop design that allows for low-pressure loss of around 3.1 Feet Head @ 10 GPM.
Direct Drive Motors
The hydronic air handler features three-phase Direct Drive Motors using different speeds. This means the handler doesn’t need any start-up capacitor, making t more energy efficient. The motor only utilizes what it exactly requires at all times and is powerful enough to deliver around 1750 cubic of air feet per minute. Remember that, the single-phase power is converted to three-phase for the motor through the VFD controller.
VFD Controller
Arctic Hydronic Air Handlers uses WAG Variable Speed Drive Controller that converts single phase 120 VAC to efficient three-phase power for the operation of the fan motor. It’s responsible for modulating power output matching the load. However, that should be less than 100 watts on constant fan speed.
The handlers have easy touch settings that can allow you to program individual fan speed settings for heating, cooling and fan only mode. The handler monitors and adjusts the static pressure of the heating or cooling system as per the changes like closed vents or dirty filters.
Working Principle
Variable Speed Fan Control allows hydronic air handler to cover a much larger spectrum effortlessly. The Arctic LV-Z-1750 can produce 3.5-5 tons of heating or cooling whereas the smaller LV-Z1050 can supply 1.5-3 tons of heating or cooling.
The VFD hydronic air handler comes with a built-in static pressure sensor that can allow you to set optimum fan speed automatically for the given house design. This means it can eliminate the need of size of the fan to the duct size virtually.
You can allow it to automatically set the best speed for any given construction or adjust the speed manually. All this is done by measuring the static pressure and optimizing the flow curve base on that static pressure.
Final Consideration –
Do you want to buy Arctic series hydronic air handlers? If yes, you should look no further than Arctic Heat Pumps. We have the best selection of hydronic air handlers available for you to choose from. For more information, please visit our website. .
A combination boiler is not ideal for a household where there are multiple people who might want to use hot water simultaneously.
ReplyDeleteboiler cooling treatment service in Ontario